HR12-42Ah | |||
Nominal Voltage | 12V (6 cells per unit) | ||
Capacity affected by Temperature (10 hour ) | 40ºC | 102% | |
25ºC | 100% | ||
0ºC | 85% | ||
-15ºC | 65% | ||
Watts/cell@15min | 170W | ||
Capacity @ 25ºC | 10 hour rate (4.2A) | 42Ah | |
5 hour rate (7.7A) | 38.5Ah | ||
1 hour rate (28.2A) | 28.2Ah | ||
Internal Resistance | Full Charged Battery@ 25ºC | ≤9.5mΩ | |
Self-Discharge@25ºC(77°F) Capacity | after 3 month storage | 90% | |
after 6 month storage | 80% | ||
after 12 month storage | 62% | ||
Charge (Constant Voltage) @ 25ºC | Standby Use | Initial Charging Current Less than 8.4A Voltage 13.6-13.8V | |
Cycle Use | Initial Charging Current Less than 8.4A Voltage 14.4-14.9V | ||
Dimension (mm*mm*mm) | Length 198±1 * Width 166±1 * Height 174±1 (Total Height 174±1) | ||
Weight (kg) | 13.8±3% |
Component | Positive plate | Negative plate | Containe r &Cover | Safety valve | Terminal | Separator | Electrolyte | Pillar seal |
Features | Thick high Sn low Ca grid with Special paste | Balanced Pb-Ca grid for improved recombinati on efficiencv |
Fire resistanc e ABS (UL94-V0octional) | Flame Si-Rubber and aging resistance |
Female Copper lnsert | Advanced PVC /AGM separator for high pressure cell desbm |
Silicon Gel | Two layers epoxy resin seal |