Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada

Product Details
Customization: Available
Type: Deep Cycle Gel Battery
Usage: off Grid Solar, UPS, Golf Car
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
3 languages freely used by foreign trade staff. include: English, Spanish, Russian
Experienced Team
The supplier has 11 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (20)
  • Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
  • Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
  • Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
  • Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
  • Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
  • Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
Find Similar Products

Basic Info.

Model NO.
FB12-80G
Discharge Rate
0.2-0.5c
Shape
Slim ***Add Favorites Get Free Gift***
Electrolyte
Gel+Acid
Installation
Fixed
Rechargeable
Chargeable
Size
562*114*188*188
Color
Red / Dark Gray
Voltage
12V
Weight
25.1kgs/25.4kgs
Warranty
2 Years
Expected Cycle Life
15~20 Years
Delivery
7 Days
Mark
12V Agmsolar Battery
Model
Lead Acid Battery 12V80ah
Certificates
Ce, IEC, ISO
Transport Package
Lead Acid Battery Carton
Specification
CE, UL, ISO, VDS
Trademark
CSBattery OEM
Origin
Guangzhou, Guangdong
HS Code
8507200000
Production Capacity
1000000PCS/Month

Packaging & Delivery

Package Size
562.00cm * 114.00cm * 188.00cm
Package Gross Weight
25.400kg

Product Description


Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
CSBattery Front Terminal AGM/GEL battery FB Series
 
FB12V Telecom Front Access Terminal Slim AGM/Gel battery, own 10-15years long life, best partner for solar and Telecom project. 
CSBattery FB12 series of 12V AGM/GEL  batteries are recognized as the most reliable and high quality battery system in the industry. They are designed with advanced patented AGM/GEL technology, Long service life designed with 10-15 years, 50% DOD 800/agm-1200/GEL Cycles, the batteries comply to the most popular international standards, such as IEC60896-21/22, BS6290-4, Eurobat Guide. 

Front terminal Batteries 12V100Ah, 150Ah, 200Ah most popular models Advanced Features:
Ø Environmentally friendly         Ø Completely Maintenance-Free        ØNon-Spillable construction design.  
Ø Wide Operating Temperature Range(-20°C~+60°C)         Ø Longer Life(20years designed life)          Ø Explosion Proof 
Ø Valve Regulated & High Discharge Rate Capability         Ø Low Self Discharge         Ø Independent of Position
Ø Ease of Shipment         Ø No need of balanced charge or boost         Ø No Memory 


Chinese Best Quality Solar GEL Battery Sunny Battery Applications:
Ø Communication equipment  Ø Telecommunication control equipment Ø Emergency lighting systems   Ø Electric power systems Ø Power station
Ø Nuclear power station Ø Solar powered and wind powered systems  Ø Load leveling and storage equipment  Ø  Marine equipment  Ø Power generation plants
Ø Alarm systems ØUninterruptible power supplies and stand-by power for computers Ø Medical equipment  Ø Fire and security systems Ø Control equipment
Ø Stand-by electric power.
CSBattery Front Terminal VRLA GEL Battery FB12-80

------------------------------------------------------------------------
CSBattery Front Terminal VRLA GEL Battery FB12-80 sepcification
FB12G-80
Nominal Voltage  12V (6 cells per unit)
Design Floating Life @ 25ºC  12 Years
Nominal Capacity @ 25ºC  10 hour [email protected],10.8V 80Ah
Capacity @ 25ºC 20hour rate (4.24A,10.8V)  84.8Ah
5 hour rate (14.1A,10.5V)  70.5Ah
1 hour rate (51.0A,9.6V)  51.0Ah
Internal Resistance  Full Charged Battery@ 25ºC  ≤6.9
Ambient Temperature Discharge  -20ºC~60ºC
Charge  -10ºC~60ºC
Storage  -20ºC~45ºC
Max.Discharge Current @ 25ºC 480A(5s)
Capacity affected by Temperature (10 hour ) 40ºC  105%
25ºC  100%
0ºC  85%
-15ºC 65%
Self-Discharge@25ºCper Month  3%
Charge (Constant Voltage) @ 25ºC Standby Use  Initial Charging Current Less than 20.0A Voltage 13.6-13.8V
Cycle Use Initial Charging Current Less than 20.0A Voltage 14.4-14.9V
Dimension (mm*mm*mm) Length(mm) 562±1 Width(mm) 114±1 Height(mm) 188±1 Total Heigth(mm) 188±1
Weight (kg)  Weight(kg) 25.5±3%

Product specifications and models
----------------------------------------------------------
Front terminal 12V  SEALED FREE MAINTENANCE GEL BATTERY
Model Nominal Voltage (V) Capacity (Ah)  Dimension (mm) Net Weight Gross Weight Terminal
Length Width Height Total Height kgs kgs
FB12-55G 12 55/10HR 277 106 223 223 16.1 16.4 M6
FB12-80G 12 80/10HR 562 114 188 188 25.1 25.4 M6
FB12-100G 12 100/10HR 507 110 223 223 29.6 30 M8
FB12-105G 12 105/10HR 394 110 286 286 30.7 31.1 M8
FB12-125G 12 125/10HR 552 110 239 239 38.2 38.6 M8
FB12-150G 12 150/10HR 551 110 288 288 44.2 44.7 M8
FB12-160G 12 160/10HR 551 110 288 288 44.7 45.2 M8
FB12-175G 12 175/10HR 546 125 316 323.5 53.7 54.2 M8
FB12-180G 12 180/10HR 560 125 316 316 55.2 55.7 M8
FB12-200BG 12 200/10HR 560 125 316 316 57.2 57.7 M8
FB12-200AG 12 200/10HR 560 125 316 316 58.2 58.7 M8

CSBattery Product Structure 
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
Component Positive plate Negative plate Containe r &Cover Safety valve Terminal Separator Electrolyte Pillar seal
Features  Sn low Ca grid with Special paste Balanced Pb-Ca grid
for improved recombinati on efficiencv
Fire resistanc e ABS (UL94-V0octional) Flame
Si-Rubber and aging resistance
Female Copper lnsert Advanced PVC /AGM
separator for high pressure cell desbm
AGM(Lead Acid)/
GEL Silicon Gel
Two layers epoxy resin seal
        Ø Positive plate : Sn low Ca 3D flat pasted plate                                   Ø Negative plate : Balanced Pb-Ca grid and AM with Supper-C addtives
         Ø Separator : Imported Amer-sil PVC separator for Gel battery        Ø Electrolyte : nano GEL electrolyte                                                                   
         Ø Battery container and cover : ABS for higher temperature             Ø Pillar seal : 100% factory tested, proven two layers epoxy resin seal           
         Ø Relief valve : Complete with integrated flame arrestor


CSBattery Assembling
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada

CSBattery Quality Control 
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
CSBattery Projects 
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada

CSBattery Certifications

Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
Ø  IEC 60896-21/22                 Ø  IEC 61427     Ø  ISO9001/14001/18001        Ø  Eurobat guide, long life     Ø  BS6290 part 4                       
Ø  GB/T 22473                          Ø  CE                  Ø  MH63727-UL

CSBattery Applications
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/AdaØ Electric Powered Vehicles          Ø Wheel Chairs           Ø BTS Stations           Ø Medical Equipment           Ø Solar and Wind           Ø Golf Cars and Buggies  
Ø Power Tools           Ø Control System           Ø UPS systems           Ø Emergency systems 

CSBattery Factory 
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
CSBattery ENERGY CO.,LIMITED is a professional manufacturer and exporter of environmental friendly Rechargeable Deep Cycle AGM Sealed Lead Acid (SLA) Batteries, Solar GEL Batteries, Front Terminal Battery, High Temperature long life GEL battery, OPzV Battery, Car/Auto Batteries, Telecom Batteries, Lithium batteries and other Solar related products such as Solar inverter, Solar charger controller, Solar panel and so on.

CSBattery Customers 
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada

CSBattery Safe Packing 
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada
CSBattery FAQ
---------------------------------------------------
                Ø Q1. Can your battery be delivered by sea and air?
                A: Yes, our batteries can be delivered both by sea and by air. We have MSDS, test report for safe transport as non-dangerous products.
                Ø Q2. Can I put my logo on the battery?
                A: Yes, you can print your logo on our batteries when you order reach 20ft container quantity. If not, price will be negotiated.
                Ø Q3. Can I fast charge my battery?
                A: Fast charging is not recommended as ifs harmful for the battery.
                ØQ4. Can I do a partial replacement of my batteries?
                A: Partial battery replacement of lead acid battery banks is not recommended.
                Ø Q5. How about your delivery time usually?
                A: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products.
                Ø Q6. Are you a battery manufacturer, and do you produce the plate by yourself ?
                A: Yes, we are a professional battery manufacture in Guangdong Province, China. And we produce plates by ourselves.
                Ø Q7. What certificate your company have?
                A: ISO 9001, ISO 14001, OHSAS 18001, CE, UL, IEC 61427 test report, Patent for gel technology and other Chinese honor.
                Ø Q8.What is your warranty time for VRLA battery ?
                A: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.
                Ø Q9. Why battery has different capacity at different hour rate?
                A: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current. For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A. With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.
                Ø Q10. What is the shelf life of VRLA battery and how to maintain the battery?
                A: The limiting factor of battery's shelf life is the rate of self-discharge which itself is temperature dependent. VRLA batteries will self-discharge less than 3% per month at 77° F (25° C). VRLA batteries should not be stored for more than 6 months at 77° F (25° C) without recharged. If in hot temperature, recharge it every 3 month. When batteries are taken out of long storage, it is recommended to recharge before use.
                Ø Q11. How does your factory control the quality?
                A: We Adopt ISO 9001 quality system to control the quality. We have Incoming Quality Control (IQC) department to test and confirm raw material meets high quality producing requirements, Production Quality Control (PQC) department contains The first Inspection, In-process quality control, acceptance inspection and full inspection, Outgoing Quality Control (OQC) department confirm no defective batteries come out from the factory.

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Inquiry US And Choose Your Gift Now ^.^
Csbattery 12V80ah Bateria Sealed Valve Regulated Gel Battery for Telecom/Solar-System/Control-Equipments/UPS-Systems/Ada

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier